  "tool": "haql-qc",
  "tool_version": "0.4.1",
  "ruleset_version": "1.2.0",
  "input": {
    "path": "/tmp/tmpkj4ckurw/tiny.csv",
    "sha256": "997b5aa659fdf44e0feafbd7cdefb1050c42b94e02da99a0edc9ad58561ab78a",
    "rows_read": 4,
    "wells_seen": 2
  },
  "run": {
    "started": "2026-10-01T23:27:44+00:00",
    "finished": "2026-10-01T23:27:44+00:00"
  },
  "config": {
    "ingest": {
      "tool": "haql-qc",
      "tool_version": "0.4.1",
      "source": {
        "path": "/tmp/tmpkj4ckurw/tiny.csv",
        "sha256": "997b5aa659fdf44e0feafbd7cdefb1050c42b94e02da99a0edc9ad58561ab78a",
        "detected_format": "csv",
        "detection_reason": "comma-delimited text with a consistent field count",
        "member": null,
        "sheet": null,
        "header_row": 1,
        "available_sheets": [],
        "rows_extracted": 4,
        "truncated": false
      },
      "schema": {
        "roles": {
          "date": {
            "role": "date",
            "column": "DATEPRD",
            "confidence": "high",
            "basis": "exact match to known date name 'dateprd'; confirmed against column contents",
            "verified": false
          },
          "gas": {
            "role": "gas",
            "column": "BORE_GAS_VOL",
            "confidence": "medium",
            "basis": "column name names the fluid",
            "verified": false
          },
          "oil": {
            "role": "oil",
            "column": "BORE_OIL_VOL",
            "confidence": "medium",
            "basis": "column name names the fluid",
            "verified": false
          },
          "uptime": {
            "role": "uptime",
            "column": "ON_STREAM_HRS",
            "confidence": "high",
            "basis": "name declares uptime in hours ('onstreamhrs'); confirmed against column contents",
            "verified": false
          },
          "water": {
            "role": "water",
            "column": "BORE_WAT_VOL",
            "confidence": "medium",
            "basis": "column name names the fluid",
            "verified": false
          },
          "well": {
            "role": "well identifier",
            "column": "WELL",
            "confidence": "high",
            "basis": "exact match to known well-identifier name 'well'; confirmed against column contents",
            "verified": false
          }
        },
        "cadence": {
          "granularity": "daily",
          "confidence": "medium",
          "basis": "successive dates are one day apart"
        },
        "units_declared_by_file": {},
        "units_declared_by_operator": {},
        "unit_sources": {},
        "needs_confirmation": [
          {
            "role": "well identifier",
            "column": "WELL",
            "confidence": "high",
            "basis": "exact match to known well-identifier name 'well'; confirmed against column contents",
            "verified": false
          },
          {
            "role": "date",
            "column": "DATEPRD",
            "confidence": "high",
            "basis": "exact match to known date name 'dateprd'; confirmed against column contents",
            "verified": false
          },
          {
            "role": "uptime",
            "column": "ON_STREAM_HRS",
            "confidence": "high",
            "basis": "name declares uptime in hours ('onstreamhrs'); confirmed against column contents",
            "verified": false
          }
        ],
        "unresolved": [],
        "notes": []
      },
      "role_overrides": {},
      "warnings": [],
      "notes": [],
      "generated": "2026-10-01T23:27:44+00:00"
    },
    "granularity": "daily",
    "well_column": "WELL",
    "date_column": "DATEPRD",
    "year_column": null,
    "month_column": null,
    "numeric_columns": [
      "BORE_GAS_VOL",
      "BORE_OIL_VOL",
      "BORE_WAT_VOL",
      "ON_STREAM_HRS"
    ],
    "text_columns": [],
    "units_declared_by_file": {}
  },
  "summary": {
    "rows_read": 4,
    "wells_seen": 2,
    "issue_count": 5,
    "by_severity": {
      "critical": 0,
      "high": 4,
      "medium": 0,
      "low": 0,
      "info": 1
    },
    "by_rule": {
      "QC014_SHUTIN_PRODUCTION": 3,
      "QC010_NEGATIVE_RATE": 1,
      "QC015_IMPLAUSIBLE_RATE": 1
    },
    "auto_correctable": 0,
    "corrections_applied": 0
  },
  "issues": [
    {
      "rule_id": "QC010_NEGATIVE_RATE",
      "well_id": "25/1-A-1",
      "date": "2024-01-02",
      "severity": "high",
      "message": "negative volume in 'BORE_OIL_VOL'",
      "source_row": 4,
      "column": "BORE_OIL_VOL",
      "observed": -5.0,
      "expected": ">= 0",
      "unit": null,
      "auto_correctable": false,
      "suggestion": "confirm sign convention before flipping; negative production volume is not physically realisable",
      "correction": "none",
      "original_value": "-5",
      "context": {
        "injection": false
      }
    },
    {
      "rule_id": "QC014_SHUTIN_PRODUCTION",
      "well_id": "25/1-A-1",
      "date": "2024-01-03",
      "severity": "high",
      "message": "ON_STREAM_HRS = 0 but 'BORE_OIL_VOL' = 105, 105% of this well's typical 100; the well cannot be producing",
      "source_row": 5,
      "column": "BORE_OIL_VOL",
      "observed": 105.0,
      "expected": "0 when the well is not producing",
      "unit": null,
      "auto_correctable": false,
      "suggestion": "either ON_STREAM_HRS is wrong or 'BORE_OIL_VOL' is. A shut-in well should report zero across all rate columns",
      "correction": "none",
      "original_value": "105",
      "context": {
        "uptime_column": "ON_STREAM_HRS",
        "uptime_value": 0.0,
        "volume_column": "BORE_OIL_VOL",
        "volume_value": 105.0,
        "well_median_for_column": 100.0,
        "ratio_to_well_median": 1.05,
        "material": true
      }
    },
    {
      "rule_id": "QC014_SHUTIN_PRODUCTION",
      "well_id": "25/1-A-1",
      "date": "2024-01-03",
      "severity": "high",
      "message": "ON_STREAM_HRS = 0 but 'BORE_WAT_VOL' = 52, 104% of this well's typical 50; the well cannot be producing",
      "source_row": 5,
      "column": "BORE_WAT_VOL",
      "observed": 52.0,
      "expected": "0 when the well is not producing",
      "unit": null,
      "auto_correctable": false,
      "suggestion": "either ON_STREAM_HRS is wrong or 'BORE_WAT_VOL' is. A shut-in well should report zero across all rate columns",
      "correction": "none",
      "original_value": "52",
      "context": {
        "uptime_column": "ON_STREAM_HRS",
        "uptime_value": 0.0,
        "volume_column": "BORE_WAT_VOL",
        "volume_value": 52.0,
        "well_median_for_column": 50.0,
        "ratio_to_well_median": 1.04,
        "material": true
      }
    },
    {
      "rule_id": "QC014_SHUTIN_PRODUCTION",
      "well_id": "25/1-A-1",
      "date": "2024-01-03",
      "severity": "high",
      "message": "ON_STREAM_HRS = 0 but 'BORE_GAS_VOL' = 2050, 102% of this well's typical 2000; the well cannot be producing",
      "source_row": 5,
      "column": "BORE_GAS_VOL",
      "observed": 2050.0,
      "expected": "0 when the well is not producing",
      "unit": null,
      "auto_correctable": false,
      "suggestion": "either ON_STREAM_HRS is wrong or 'BORE_GAS_VOL' is. A shut-in well should report zero across all rate columns",
      "correction": "none",
      "original_value": "2050",
      "context": {
        "uptime_column": "ON_STREAM_HRS",
        "uptime_value": 0.0,
        "volume_column": "BORE_GAS_VOL",
        "volume_value": 2050.0,
        "well_median_for_column": 2000.0,
        "ratio_to_well_median": 1.025,
        "material": true
      }
    },
    {
      "rule_id": "QC015_IMPLAUSIBLE_RATE",
      "well_id": "",
      "date": "",
      "severity": "info",
      "message": "3 column(s) skipped for plausibility: unit not declared, so readings were not converted to a comparable unit",
      "source_row": 0,
      "column": "BORE_GAS_VOL,BORE_OIL_VOL,BORE_WAT_VOL",
      "observed": "BORE_GAS_VOL,BORE_OIL_VOL,BORE_WAT_VOL",
      "expected": "declare a unit, e.g. --declare-unit BORE_OIL_VOL=Sm3",
      "unit": null,
      "auto_correctable": false,
      "suggestion": "add --declare-unit <COLUMN>=<UNIT> to cover these columns",
      "correction": "none",
      "original_value": null,
      "context": {
        "skipped_columns": [
          "BORE_GAS_VOL",
          "BORE_OIL_VOL",
          "BORE_WAT_VOL"
        ]
      }
    }
  ]
}